Wood stove Polar 5-2.0

  • Rear Air Control
  • Door for wood log storage
  • Air-flowe handle
  • Air control unit rear side top
  • Standard external combustion air connection

The connecting piece for external combustion air supply is not included in the scope of delivery


Technical details

Energy efficiency class A+
Connection possibility top / rear
Operation with external air supply rear / bottom
Nominal heat output 5,0 kW
Weight (incl. packaging) steel 105 kg
Weight (incl. packaging) stone 154 kg
Room heating capacity up to 88 m³
Length of logs 25 cm
Exhaust gas mass flow 5,7 g/s
Exhaust temperature 266 °C
Required delivery pressure 0,12 mbar
Height 1064 (steel), 1082 (stone) mm
Width 506 (steel) / 511 (stone) mm
Depth 382 (steel) / 381 (stone) mm
Efficiency >80 %

Accessories for your Wood stove Polar 5-2.0


Downloads

5445_Polar5_2_CE marking
PDF 281.56 KB
Download
5445_Polar5_2_Declaration of performance
pdf 148.51 KB
Download
5445_Polar5_2_EU data sheet
pdf 61.63 KB
Download
5445_Polar5_2_Energy label
pdf 874.78 KB
Download
5445 Polar 5 2 User manual
PDF 6.83 MB
Download
5445_Polar5_2_User manual short
PDF 6.00 MB
Download
5445 EU-Konformitätserklärung Polar 5-2.0
pdf 61.85 KB
Download

Order numbers

Steel black 5445 11
Soapstone, corpus steel black 5445 23
Sandstone, corpus steel black 5445 42
Limestone cream, corpus steel black 5445 87

Product highlights

Multi point locking system

The multi-point locking prevents warping of the fire door caused by high temperatures. In addition the special sealing prevents from unwanted air supply and and keeps the combustion quality stable in the oven.


External combustion air supply

In modern, more dense buildings with controlled ventilation systems, the combustion air must be supplied from the outside so there can not arise a vacuum in the living room. This requires a separate external air supply.

Please notice:
The simultaneous operation of a stove with solid fuels and controlled ventilations systems is only permittet, if the stove has an approval under building law as independent of ambient air stove according to DBIT. The stove has to be equiped with a security device e.g. low pressure warning device that has acces to the ventilation systems and is able to turn them off in case a vacuum arises. 

Please find more information about DBIT in the users manual.


Airwash system

A deliberately conducted airflow prevents condensation and deposition of flue gases at the inside of the glass. This keeps the window clear.


Triple-air-system

The special ORANIER triple-air-system provides for the ideally dosed air supply exactly where its needed for the combustion. The desired result is an especially clean and efficient combustion.


Air-flow handle

By air circulation through the ergonomically shaped handle the temperature at the surface is largely reduced.